Commercial buildings are strengthened when a change of use or a large alteration triggers seismic upgrades under the California Existing Building Code (CEBC), when a local retrofit ordinance requires it, when new loads are added, or when an owner wants a known weakness corrected. We evaluate the existing structure, usually following ASCE 41 where a performance-based evaluation is appropriate, locate the critical deficiencies, and design practical upgrades with stamped drawings and calculations for permit.
A complete path from roof and floor diaphragms through collectors and lateral elements to the foundation, and where it is interrupted.
Out-of-plane anchorage of masonry and concrete walls to roofs and floors, a known failure point in older tilt-up and masonry buildings.
Strength and stiffness of wood, metal deck and concrete diaphragms, including openings and chord and collector forces.
Concrete, masonry, steel and timber strengths established from drawings, field review and testing where needed.
Weak or soft stories, torsion, and abrupt changes in stiffness or strength, as defined in ASCE 7.
Which CEBC alteration level or local ordinance applies, and the force level it requires of the existing lateral system.